Residential Inspection ReportReport · May 23, 2026
Property photo
Prepared for M. & J. Carter
1428 Twin Oaks Drive
Marietta, GA 30062
This home is in generally sound condition. Of the 15 items noted in this report, 3 relate to safety and 3 are recommended for evaluation by a qualified specialist — each is detailed below by system, with photos and clear next steps.
InspectedMay 22, 2026
InspectorDaryl Hill, CPI
Year built1998
Size2,340 sq ft
FoundationCrawlspace
ConditionsClear · 78°F
Inspected by Daryl Hill · InterNACHI Certified Professional Inspector (CPI) · GA Home Inspector (770) 555-0148 · daryl@hillhomeinspections.com · Performed in general accordance with the InterNACHI Residential Standards of Practice.
At a glance
This home is well-kept overall. 15 items warrant attention — tap a category to filter the report.
01
Roofing
Major Defect
Method
Viewed from ladder at eave and from grade with binoculars; not walked due to slope and surface condition.
Limitations
Roof not traversed; areas obscured by surface debris were not fully evaluated.
Major DefectFurther evaluationRear slope
Shingle covering
Condition
Localized shingle damage and evidence of prior patching observed on the rear roof slope.
Why it matters
Active leakage was not confirmed, but the condition may allow water intrusion and can shorten the remaining service life of the covering.
What to do
Evaluation and repair by a qualified roofing contractor. — Roofing contractor.
photo
Rear roof slope — damaged shingle field with prior patch
photo
Close-up — lifted tabs at patched area
TradeRoofing contractorUrgencyBefore closing
Major DefectChimney intersection
Step / counter flashing
Condition
Damaged and improperly lapped flashing observed where the chimney meets the roof field.
Why it matters
This condition can allow water intrusion into concealed roof and wall assemblies and may lead to wood decay over time.
What to do
Repair by a qualified roofing contractor. — Roofing contractor.
photo
Chimney base — open flashing lap
TradeRoofing contractorUrgencyNear term
MaintenanceRight elevation
Gutters
Condition
Debris accumulation observed in gutters along the right elevation.
Why it matters
Restricted drainage can overflow toward the foundation and contribute to perimeter moisture.
What to do
Clean gutters and establish routine maintenance. — Owner / handyman.
TradeOwner / handymanUrgencyRoutine
02
Exterior
Safety
Method
Visual inspection of readily accessible cladding, trim, grading, and attached structures from grade.
Limitations
Areas behind stored items and dense vegetation were not fully visible.
SafetyRear deck
Guardrail
Condition
The rear deck guardrail is loose and moves under hand pressure; baluster spacing is wider than modern safety standards in one run.
Why it matters
A loose guard and wide spacing present a fall hazard, particularly for children.
What to do
Repair and reinforce the guardrail; correct spacing by a qualified contractor. — Carpenter / deck contractor.
photo
Rear deck — loose guardrail post
photo
Baluster spacing exceeds guideline
TradeCarpenter / deck contractorUrgencyImmediate
MonitorFront elevation
Fascia & door trim
Condition
Wood rot and sealant failure observed at fascia trim and the exterior door frame.
Why it matters
In Georgia’s hot, humid climate, sealant failure and decay can progress and admit moisture into the wall assembly.
What to do
Repair affected trim, re-seal, and maintain finishes. — Carpenter.
photo
Front door frame — softened, decayed trim
TradeCarpenterUrgencyNear term
MonitorFoundation perimeter
Site grading
Condition
Negative grading observed at portions of the foundation perimeter, directing surface water toward the home.
Why it matters
Poor drainage at the perimeter contributes to crawlspace moisture and foundation movement over time.
What to do
Re-grade to slope away from the foundation and extend downspout discharge. — Landscaper / grading contractor.
TradeLandscaper / grading contractorUrgencyNear term
03
Garage
Functional
Method
Visual inspection of accessible garage components and overhead door operation.
Limitations
Stored items limited visibility of walls and slab.
Functional
Overhead door operated normally and auto-reverse safety responded when tested.
04
Structure
Functional
Method
Visual inspection of readily visible structural components.
Limitations
Finished surfaces concealed most structural members.
Functional
No significant structural deficiencies observed in readily visible framing at time of inspection.
05
Crawlspace / Foundation
Monitor
Method
Entered and traversed accessible portions of the crawlspace where headroom and access allowed.
Limitations
Low-clearance areas and areas beneath HVAC ductwork were not fully accessible.
MonitorFurther evaluationBelow primary bath
Subfloor & insulation
Condition
Elevated moisture staining and fallen insulation observed below the primary bathroom area.
Why it matters
Continued moisture exposure can contribute to insulation damage, wood deterioration, and conditions favorable to microbial growth.
What to do
Perform a plumbing leak check above this area and improve crawlspace moisture management. — Plumber + crawlspace contractor.
photo
Crawlspace below primary bath — staining at subfloor
photo
Fallen batt insulation
TradePlumber + crawlspace contractorUrgencyNear term
MonitorCrawlspace floor
Vapor barrier
Condition
Vapor barrier is damaged and provides insufficient coverage over the soil.
Why it matters
Exposed soil raises crawlspace humidity and adds to the moisture load on framing.